You understand that the RCD is (mandatorily) in the electrical distribution panel where it hands off to the utility supply right?
- 0 Posts
- 3 Comments
Joined 4 months ago
Cake day: May 22nd, 2026
You are not logged in. If you use a Fediverse account that is able to follow users, you can follow this user.
Although it’s an absolute pain in the arse in certain scenarios. Surge protectors essentially present as a leak to earth any time they do their job, so my mandatory RCCBs on every circuit turn minor mains fluctuations into permanent outages.
I really need to see if I can legally run one circuit that isn’t RCD protected for my homelab…



I have a suspicion that the kind of surge protector rating it’s reasonable to fit to the main electrical input for a building is unlikely to actually trigger on the small surges that the surge protector in a UPS will, and you will still get earth-leakage trips on the RCDs with UPSs downstream of them.
Having one radial (for the computer rack) NOT protected by an RCD seems like a cheaper and more reliable solution, but I confess it’s not bubbled to the top of my to-do list yet to get a sparky involved for advice.